Next Day Delivery Details
- Next Day Delivery on this Berkey product includes FREE shipping to the lower 48 USA!
- Physical address required; no P.O. boxes.
- Orders must be completed by 12pm Pacific Time (Mon-Fri) to receive this service. While we do our best to have products arrive next day, this is not a guaranteed service.
- All orders completed from this category after 12pm Pacific Time will come in 1-2 business days.
- We strongly recommend physical receipt of delivered orders.
- USABerkeyFilters.com will not be held liable for theft resulting from “Porch Pirates” or the like.
- No Coupons may be used with Next Day Delivery.
- The Berkey Light water filter system comes standard with 2 Black Berkey Purification Elements but can be expanded up to 4 elements
- It is a lightweight unit designed for home use, travel, outdoor activities, and during unexpected emergencies
- Constructed of a non-BPA/BPS co-polyester, which does not retain or leach any foul odors into your water
- Storage capacity of about 2.75 gallons (10.4 liters)
- Maximum filters: 4 Black Berkey Elements (in upper chamber)
- System includes upper and lower chambers, a base, 2 Black Berkey Purification Elements (expandable to 4), 2 washers, 2 wingnuts, 1 priming button, 1 spigot, 1 cloth lid
- Height when in use: 21″ (when used without base); 26.5″ (with base)
- Weight: 6lbs empty
- Diameter: 9″
- For normal everyday use, this system easily serves: 1-5 people
- Fully configured, this system can serve up to 100-200 people a day, during an emergency
- Maximum Filtration Flow Rate:
- Configured with 2 Black Berkey Purification Elements, the Berkey Light system can produce up to 4 gallons ( 15.2 liters) of purified water per hour
- Configured with 4 Black Berkey Purification Elements, the Berkey Light system can produce up to 8 gallons (30 liters) of purified water per hour
- Up to 4 PF-2 Fluoride and Arsenic Reduction Filters may be installed in the lower chamber of this system if desired
Shipping Info
Free in the USA
Please e-mail or call us for shipping rates outside the US.
We ship Berkey® Products worldwide.
*Using Black Berkey® Elements with water containing mineral salts, brackish water, or saltwater voids all warranties and returns.
This System includes the New Berkey® Quick-Start Kit:
- Prime Rite™ Universal Adapter (Only for use with faucet)
- Prime Rite™ Fluoride Element Adapter
- Anti-Airlock Clip
- 2 Red Food Dye Vials
Download the Berkey Quick-Start Kit Instructions HERE.
What does Berkey® Remove?
Black Berkey® Elements Remove:
PATHOGENIC BACTERIA (AND SURROGATES) – Removed to >99.9999%
Exceeds Purification Standard (Log 6): Bacillus atrophaeus (Anthrax surrogate); Raoultella terrigena (Pathogenic Bacteria Surrogate); Salmonella Enterica.
TRIHALOMETHANES – Removed to >99.8%
(Below Lab Detectable Limits):
Bromodichloromethane ; Bromoform ; Chloroform ; Dibromochloromethane.
INORGANIC MINERALS
Removed to Below Lab Detectable Limits: Chloramine; Chloride; Chlorine Residual (Total Residual Chlorine); Free Chlorine
HEAVY METALS (HIGH & LOW pH LEVELS)
Aluminum (>99%); Antimony (>99.9%); Barium (>80%); Beryllium (>99.9%); Bismuth (>99.9%); Cadmium (>99.7%); Cobalt (>95%); Chromium (>99.9%); Chromium 6 (>99.85%); Copper (>99.9%); Iron (>99.9%); Lead (>99.9%); Mercury (>99.9%); Molybdenum (>90%); Nickel (>99.9%); Vanadium (>87.5%); Zinc (>99.9%).
PHARMACEUTICAL DRUGS CONTAMINANTS – Removed to >99.9%
Acetaminophen; Caffeine; Carbamazepine; Ciprofloxacin HCl; Erythromycin USP; Sulfamethoxazole; Trimethoprim; Bisphenol A; Diclofenac Sodium; 4-para-Nonylphenol; 4-tert-Octylphenol; Primidone; Progestrone; Gemfibrozil; Ibuprofen; Naproxen Sodium; Triclosan.
Pesticides & (Semi) Volatile Organic Compounds (VOCs) Removed to Below Laboratory Detectable Limits |
|
1,1,1,2-Tetrachloroethane 1,1,1-Trichloroethane (TCA) 1,1,2,2-Tetrachloroethane 1,1,2-Trichloroethane 1,1,2-Trichlorotrifluoroethane 1,1-Dichloroethane (1,1-DCA) 1,1-Dichloroethylene (1,1-DCE) 1,1-Dichloropropene 1,2,3-Trichlorobenzene 1,2,3-Trichloropropane 1,2,4-Trichlorobenzene 1,2,4-Trimethylbenzene 1,2-Dibromo-3-chloropropane (DBCP) 1,2-Dibromoethane 1,2-Dichloro-1,1,2-trifluoroethane (CFC 123a) 1,2-Dichlorobenzene 1,2-Dichlorobenzene-d4 1,2-Dichloroethane 1,2-Dichloropropane 1,3,5-Trimethylbenzene 1,3-Dichlorobenzene 1,3-Dichloropropene 1,4-Dichlorobenzene 2,2-Dichloropropane 2,4,5-T 2,4,5-TP (Silvex) 2,4-D 2,4-DB 2-Butanone (MEK) 2-Chlorotoluene 2-Hexanone 2-Methyl-2-propanol 3,5-Dichlorobenzoic Acid 3-Hydroxycarbofuran 4-Bromofluorobenzene 4-Chlorotoluene 4-Isopropyltoluene 4-Methyl-2-pentanone 4-Nitrophenol4,4′-DDD4,4′-DDE 4,4″-DDT 5-Hydroxydicamba Acetone Acenaphthylene Acifluorfen Alachlor Aldicarb Aldicarb Sulfone Aldicarb Sulfoxide Aldrin alpha-Chlorodane Ametryn Anthracene Aroclor (1016, 1221, 1232, 1242, 1248, 1254, 1260) Atraton Atrazine Baygon Bentazon Benzene Bromacil Bromoacetic Acid Bromobenzene Bromochloromethane Bromodichloromethane Bromomethane Bromoform Butachlor Butylate Butylbenzylphthalate Carbaryl Carbofuran Carbon Tetrachloride Carboxin Chloramben Chlordane Chloroacetic Acid Chlorobenzene Chlorobenzilate Chloroethane Chloroform Chloromethane Chlorpropham Chlorprophane cis-1,2-Dichloroethylene cis-1,3-Dichloropropene cis-Nonachlor Cycloate Dacthal Acid Dalapon Diazinona Dibromoacetic Acid Dibromochloropropane (DBCP) Dibromomethane Dicamba |
Dichloroacetic Acid Dichlorodifluoromethane (CFC 12) Dichloromethane Dichlorvos Diclorprop DieldrinDiethylphthalate Dinoseb Diphenamid Disulfoton Disulfoton Sulfone Disulfoton Sulfoxidea Endrin EPTC Ethoprop Ethylbenzene Ethylene Dibromide (EDB) Fenamiphos Fenarimol Fluorobenzene Fluridone gamma-Chlorodane Glyphosate Halo acidic Acids (HAA5) Heptachlor Heptachlor Epoxide Hexachlorobenzene Hexachlorobutadiene (CCC) Hexachlorocyclopentadiene HexazinoneIsophorone Isopropylbenzene (Cumene) Lindane (Gamma-BHC) Merphos Methiocarb Methomyl Methoxychlor Methylcyclohexane-methane Methyl Paraoxon Methyl tert-Butyl Ether (MTBE) Metolachlor Metribuzin Mevinphos MGK 264 Molinate Monochlorobenzene m-Xylenes Naphthalene Napropamide n-Butylbenzene Norflurazon n-Propylbenzene Oxamyl o-Xylene Pebulate Pentachlorophenol Picloram Prometon Prometryn Pronamidea Propazine p-Xylenes sec-Butylbenzene Simazine Simetryn Stirofos Styrene Tebuthiuron Terbacil Terbufos Terbutryn tert-Butylbenzene Tetrachloroethylene (PCE) Tetrahydrofuran (THF) Thiobencarb Toluene Toxaphene trans-1,2-Dichloroethylene trans-1,3-Dichloropropene trans-Nonachlor Triademefon Tribromoacetic Acid Trichloroacetic Acid Trichloroethene (TCE) Trichloroethylene Trichlorofluoromethane (CFC 11) Tricyclazole Trifuralin Vernolate Vinyl Chloride and many more* |
ALSO REMOVES OR REDUCES:
Arsenic (>99.9%); Escherichia coli (E. Coli) (>99.999%); Fluorene (>99.9%); Manganese (>99.9%); MBAS (>96.67%); Nitrites (>95%); PCB’s (>99.9%); Petroleum Products (Gasoline, Diesel, Crude Oil, Kerosene, Mineral Spirits, Refined Oil- All >99.9%); Selenium (>99.9%); Thallium (>99.5%); Rust; Silt; Sediment; Turbidity; Foul Tastes and Odors.
* For Heavy Metals, Inorganic Minerals, Pesticides, Petroleum, Pharmaceuticals, Semi-VOC’s, THM’s, VOC’s; reduction exceeded lab detection limits.
PF2 Fluoride & Arsenic Reduction Elements
Testing for fluoride was based on 20-30ppm of the ion in the influent aqueous solution at a flow rate of no more than 3 gpm per cubic foot of media. Results of ‹1ppm of the fluoride ion in the effluent were typical for the media (>95% reduction). Under optimum conditions, effluent concentrations of less than 50 ppb were readily achieved (>99.75% reduction).
Need to filter for arsenic? This product uniquely targets the entire family of arsenic oxide anions as well as the arsenic cations.
REPLACEMENT:
Under normal conditions it is recommended that each set of two PF-2 elements be replaced after 1,000 gallons (the Berkey Light®️ is 2.5 gallons therefore the PF-2 filters should be replaced after 400 refills. If the system is refilled about one time per day, the PF-2’s should be replaced annually, if the system is refilled about twice per day, the PF-2’s should be replaced about every six months). Actual capacity is dependent on the presence of other competing contaminants in the source water. High levels of Fluoride, arsenic and heavy metals may reduce the capacity and efficiency of the elements.
Reviews
There are no reviews yet.